Electric shock

LED lamp tube

Eco Light Nordic
LED lamp tubeLED lamp tube
Číslo případu
0966/10
Kategorie
Lighting equipment
Typ / Model
1100-LED-TUBE-SMD-T10-18W-1200mm
Cílová skupina
Consumer
Notifikující země
🇸🇪 Švédsko
Země původu
Unknown
Zveřejněno
2010-06-25

⚠️ Riziko

The product poses a risk of electric shock because:- during mounting the free-end connector of the LED tube might be live;- the clearance and the creepage distances are not sufficient;- the insulation resistance is not sufficient;- internal basic insulated conductors are in contact with the metal body of the lamp;- the mechanical strength of the silicone insulation of the conductors is weak and can be easily damaged.The product does not comply with the Low Voltage Directive (LVD) and the relevant European standard EN 60598.

Opatření

Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Withdrawal from the market and recall from consumers ordered by the authorities.Date of entry into force: Unknown

LED lamp tube intended to replace a traditional fluorescent tube in the original (existing) luminaire.