Electric shock

Fluorescent desk lamp

Unknown
Fluorescent desk lampFluorescent desk lampFluorescent desk lamp
Číslo případu
A12/1003/14
Kategorie
Lighting equipment
Typ / Model
Unknown
Šarže
Unknown.
Cílová skupina
Consumer
Notifikující země
🇭🇺 Maďarsko
Země původu
🇨🇳 Čína
Zveřejněno
2014-07-04

⚠️ Riziko

null The product poses a risk of electric shock as the openings for the cable are not fitted with wire insulating sleeves and wire clamps are not used for the internal wiring, which can come into contact with sharp metal edges. The live contacts of the fluorescent tube sockets can be touched when the tube is changed and the insulation between the live parts and the accessible parts of the product is not sufficient.The product does not comply with the requirements of the Low Voltage Directive and the relevant European standard EN 60598.

Opatření

Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Withdrawal of the product from the marketDate of entry into force: UnknownType of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Recall of the product from end usersDate of entry into force: 13/05/2014

Fluorescent desk lamp with a T4 fluorescent tube. Technical parameters: 220 V - 240 V/50 Hz; 1x20 W G5. Label on product: "DESK LAMP". Packaging: cardboard box.