Lighting chain
Unknown
- Číslo případu
- A12/1482/14
- Kategorie
- Lighting chains
- Typ / Model
- Unknown
- Šarže
- 5792013 038174
- Cílová skupina
- Consumer
- Notifikující země
- 🇭🇺 Maďarsko
- Země původu
- 🇨🇳 Čína
- Zveřejněno
- 2014-09-26
⚠️ Riziko
null The cross sectional area of the external and internal wires is too small and the wires could overheat. The wire ends soldered to the terminals of the flashing unit and the LEDs are not adequately protected against pulling and twisting. The accessible basic insulated wires can come into contact with sharp edges of the flashing switch and control unit. The insulation of the light sources covering shrink tube is inadequate. The product is not protected against moisture but is recommended for outdoor use. The product does not comply with the requirements of the Low Voltage Directive and the relevant European standard EN 60598.
Opatření
Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Withdrawal of the product from the marketDate of entry into force: UnknownType of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Recall of the product from end usersDate of entry into force: 15/08/2014