Electric shock, Fire

Portable radio

Waxiba
Portable radioPortable radio
Číslo případu
A12/0662/15
Kategorie
Communication and media equipment
Typ / Model
XB-909U
Šarže
Unknown.
Cílová skupina
Consumer
Notifikující země
🇭🇺 Maďarsko
Země původu
🇨🇳 Čína
Zveřejněno
2015-05-29

⚠️ Riziko

null Touchable metal parts (telescopic antenna, AUX IN socket) may become live while charging the radio. The dimensions of the socket outlet and the flat plug are not suitable and live parts can be touched as a result. The cross-sectional area of the conductors in the cable is too small. The cable could thus overheat causing a fire.The product does not comply with the requirements of the Low Voltage Directive and the relevant European standard EN 60065.

Opatření

Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Withdrawal of the product from the marketDate of entry into force: UnknownType of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Recall of the product from end usersDate of entry into force: 03/01/2015

A portable radio which operates via the mains supply and on batteries. Packaging: a colourful cardboard box.