Electric shock, Fire

Lighting chain

Unknown
Lighting chainLighting chainLighting chain
Číslo případu
A12/1633/15
Kategorie
Lighting chains
Typ / Model
RO-KAF-A03
Šarže
1410380165
Cílová skupina
Consumer
Notifikující země
🇭🇺 Maďarsko
Země původu
🇨🇳 Čína
Zveřejněno
2015-12-18

⚠️ Riziko

null The cross-sectional area of the external and internal wires is too small and the wires could overheat. The dimensions of the plug are substantially less than required. The wire ends soldered to the terminals of the flashing unit and the LEDs are not adequately protected against pulling and twisting. The accessible basic insulated wires can come into contact with sharp edges of the flashing switch and control unit. The insulation provided by the shrink tubing for the lamps is inadequate. The product does not comply with the requirements of the Low Voltage Directive and the relevant European standard EN 60598.

Opatření

Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Withdrawal of the product from the marketDate of entry into force: UnknownType of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Recall of the product from end usersDate of entry into force: 21/07/2015

Lighting chain 240 blue LED lamps. Packaging: colourful cardboard box.