Injuries

Concrete mixer pump

Cifa
Concrete mixer pumpConcrete mixer pump
Číslo případu
A12/1191/16
Kategorie
Machinery
Typ / Model
MK28.4.L 4Z/115RH, manufactured in 2007
Šarže
serial number: 12199
Cílová skupina
Professional
Notifikující země
🇵🇱 Polsko
Země původu
🇮🇹 Itálie
Zveřejněno
2016-09-30

⚠️ Riziko

null The strength of the outrigger pillar is insufficient due to a fault of the structure material. During pouring of concrete, when the boom of the pump is in its maximum horizontal position, the construction breaks and hits workers who are present in the working zone of the boom. The product does not comply with the requirements of the Machinery Directive.Four fatal accidents were reported.

Opatření

Type of economic operator taking notified measure(s): OtherCategory of measure(s): Recall of the product from end usersDate of entry into force: Unknown

Product is installed on the chassis of the truck and intended for mixing and dispensing of concrete.